Description
Usually called silicone uniform heating plate, a newly designed space heater product, its basic structure is a silicone glass cloth with uniformly distributed electric heating elements. The heat generated by it is quickly transferred to an aluminum plate of the same size as silicone, and the silicone glass cloth and aluminum metal plate are integrated to form a heat conduction (dissipation) device. Through the aluminum metal plate, the heating conduction efficiency and heat distribution are increased, avoiding local silicone overheating, Furthermore, heat transfer can be achieved in the component space where a silicone uniform heating plate is installed.
1. Ultra thin, occupying small device space, exquisite and beautiful, in line with the usage style in the specialized industry.
2. The heat transfer of the heat source is relatively uniform, without the occurrence of local high temperatures, which is beneficial for improving equipment safety and the service life of the heat source.
Technical Parameter
Technical Specification Sheet for Silicone Uniform Heater | |
Operation voltage | 110V、220V、230V、380V |
Power | 50W、100W、200W、250W |
Current | <0.5mA |
Insulation resistance | >50MΩ(DC 500V) |
power-frequency withstand voltage | 1500V/1min with No breakdown |
Thermal conductor material | Silicone rubber+aluminum plate |
Surface power load | Usually, the surface load is controlled at≤0.66W/cm2,0.6 ~0.8 W/cm2 |
Standard exterior dimensions | 300mm*150mm*3.6mm; |
Lead specifications | The standard type is silicone flat sheath wire 2 * 0.75mm2, which can be customized by users based on power/voltage |
Surface temperature | Different surface temperatures under static air Q/flowing air L conditions。 |
Technical information is subject to change without prior notice. Matters not covered, refer to JB/T 2379-2016 |
(1)、For example, 313015-0250/230-4500 refers to the ordering data of the 313015 type uniform heater, with the structure code of the thermal conductor being 31. The thermal conductor is composed of silicone gel and thermal conductive aluminum plate, with a standard thickness of 2mm for the thermal conductive aluminum plate; 3015 refers to the overall dimensions of the product (size of the heat exchanger): length (L) * width (W)=30cm * 15cm; Nominal power: 250w; Working voltage: 230v; The lead length LW=4500 mm, without mounting bracket.
(2)The standard type of silicone uniform heating plate is set to facilitate design and selection; This series of products can be customized by customers, but the surface power load needs to be controlled between 0.6~0.8 W/cm2, and ≤ 0.66W/cm2 is better. The installation interface or bracket requirements......etc can be defined by customers.
(3)If the structure code of the heat exchanger is 30, it indicates that there is no matching heat conductive aluminum plate in the heat exchanger, and the silicone backing only has 3M double-sided tape.
Ordering code | Power(W) | Lead length(Lw,mm) | Dimensions (LR,cm) | Bracket model code | Temperature grade |
313015-100/230-1000 | 100W | 1 | 30*15 | - | |
313015-200/230-5000 | 200W | 5 | 30*15 | - | |
313015-250/230-5000 | 250W | 4.5 | 30*15 | - | |
313015-100/380-1000 | 100W | 1 | 30*15 | - | |
313015-200/380-5000 | 200W | 5 | 30*15 | - | |
313015-250/380-1000 | 250W | 1 | 30*15 | - | |
Heating power, overall dimensions, cable length, installation brackets, etc. can be customized as needed, please refer to the ordering code description. The standard thickness of thermal conductive aluminum plate is 2mm. Technical information is subject to change without prior notice. |
Description
Usually called silicone uniform heating plate, a newly designed space heater product, its basic structure is a silicone glass cloth with uniformly distributed electric heating elements. The heat generated by it is quickly transferred to an aluminum plate of the same size as silicone, and the silicone glass cloth and aluminum metal plate are integrated to form a heat conduction (dissipation) device. Through the aluminum metal plate, the heating conduction efficiency and heat distribution are increased, avoiding local silicone overheating, Furthermore, heat transfer can be achieved in the component space where a silicone uniform heating plate is installed.
1. Ultra thin, occupying small device space, exquisite and beautiful, in line with the usage style in the specialized industry.
2. The heat transfer of the heat source is relatively uniform, without the occurrence of local high temperatures, which is beneficial for improving equipment safety and the service life of the heat source.
Technical Parameter
Technical Specification Sheet for Silicone Uniform Heater | |
Operation voltage | 110V、220V、230V、380V |
Power | 50W、100W、200W、250W |
Current | <0.5mA |
Insulation resistance | >50MΩ(DC 500V) |
power-frequency withstand voltage | 1500V/1min with No breakdown |
Thermal conductor material | Silicone rubber+aluminum plate |
Surface power load | Usually, the surface load is controlled at≤0.66W/cm2,0.6 ~0.8 W/cm2 |
Standard exterior dimensions | 300mm*150mm*3.6mm; |
Lead specifications | The standard type is silicone flat sheath wire 2 * 0.75mm2, which can be customized by users based on power/voltage |
Surface temperature | Different surface temperatures under static air Q/flowing air L conditions。 |
Technical information is subject to change without prior notice. Matters not covered, refer to JB/T 2379-2016 |
(1)、For example, 313015-0250/230-4500 refers to the ordering data of the 313015 type uniform heater, with the structure code of the thermal conductor being 31. The thermal conductor is composed of silicone gel and thermal conductive aluminum plate, with a standard thickness of 2mm for the thermal conductive aluminum plate; 3015 refers to the overall dimensions of the product (size of the heat exchanger): length (L) * width (W)=30cm * 15cm; Nominal power: 250w; Working voltage: 230v; The lead length LW=4500 mm, without mounting bracket.
(2)The standard type of silicone uniform heating plate is set to facilitate design and selection; This series of products can be customized by customers, but the surface power load needs to be controlled between 0.6~0.8 W/cm2, and ≤ 0.66W/cm2 is better. The installation interface or bracket requirements......etc can be defined by customers.
(3)If the structure code of the heat exchanger is 30, it indicates that there is no matching heat conductive aluminum plate in the heat exchanger, and the silicone backing only has 3M double-sided tape.
Ordering code | Power(W) | Lead length(Lw,mm) | Dimensions (LR,cm) | Bracket model code | Temperature grade |
313015-100/230-1000 | 100W | 1 | 30*15 | - | |
313015-200/230-5000 | 200W | 5 | 30*15 | - | |
313015-250/230-5000 | 250W | 4.5 | 30*15 | - | |
313015-100/380-1000 | 100W | 1 | 30*15 | - | |
313015-200/380-5000 | 200W | 5 | 30*15 | - | |
313015-250/380-1000 | 250W | 1 | 30*15 | - | |
Heating power, overall dimensions, cable length, installation brackets, etc. can be customized as needed, please refer to the ordering code description. The standard thickness of thermal conductive aluminum plate is 2mm. Technical information is subject to change without prior notice. |